Working with our Vertiv Sales team enables complex designs to be configured to your unique needs. If you are an organization seeking technical guidance on a large project, Vertiv can provide the support you require.

Learn More

Many customers work with a Vertiv reseller partner to buy Vertiv products for their IT applications. Partners have extensive training and experience, and are uniquely positioned to specify, sell and support entire IT and infrastructure solutions with Vertiv products.

Find a Reseller

Already know what you need? Want the convenience of online purchase and shipping? Certain categories of Vertiv products can be purchased through an online reseller.


Find a Reseller

Need help choosing a product? Speak with a highly qualified Vertiv Specialist who will help guide you to the solution that is right for you.



Contact a Vertiv Specialist

The page you're viewing is for Turkish (EMEA) region.

Ürün Ailesi

Arc Flash Studies

Arc flash incidents are highly concentrated radiant thermal energy resulting from an arcing fault between two points. These potentially devastating events kill or injure people every day. An up-to-date arc flash study helps mitigate these hazards by calculating the limited and restricted approach boundaries inside which workers must use appropriate personal protective equipment (PPE).

Broşürü Al
En Uygun Çalışma Alanı:
  • Data CenterColocationHosting
  • Healthcare
  • Manufacturing
  • Oil and Gas
  • Power Generation
  • PowerGas Transmission and Distribution

Avantajlar

Improved regulatory compliance results from performing arc flash hazard analysis in accordance with industry guidelines 
Improved worker safety is achieved by identifying potential hazards and implementing recommendations to mitigate risk 
Greater productivity occurs by reducing business disruption and lost man hours that can result from arc flash incidents 
Enhanced system performance results from improved maintenance practices and preventing equipment damage 

Özellikleri

Data collection includes critical equipment information that is necessary to perform accurate arc flash hazard analysis
Arc flash calculations are performed with state-of-the-art software and in accordance with the standards of NFPA and IEEE
Comprehensive report, including the results of the hazard analysis and expert recommendations, helps ensure compliance with OSHA and NFPA standards

Bölgenizdeki İlgili Kişiyi Bulun

Ürün Destek İlgili Kişileri

Şunun için ilgili kişiler gösteriliyor: Ohio, 43215, USA Değiştir
Chloride Industrial UPS Services
+1 800 442 7489
USA
Odaklanılan hizmet alanları: Performans Optimizasyon Hizmetleri, Endüstriyel Uygulamalar için Önleyici Bakım
Emergency Response for Services
+1 800 543 2378
USA
Odaklanılan hizmet alanları: Proje Servisleri, Performans Optimizasyon Hizmetleri
Geist Support - Americas (Rack PDU and Watchdog)
1777 Yolande Avenue Lincoln Nebraska USA
Odaklanılan hizmet alanları: Proje Servisleri, Performans Optimizasyon Hizmetleri, Acil Yanıt, Önleyici Bakım, Endüstriyel Uygulamalar için Önleyici Bakım, Uzaktan Servisler, Yedek Parçalar ve Parça Yönetimi

Sıkça Sorulan Sorular

S
What is an arcing fault?
Y
An arcing fault is the flow of current through the air between phase conductors or phase conductors and neutral or ground.
S
What causes an electrical arc?
Y
An arc occurs when electric current flows between two or more separated energized conducting surfaces. Some arcs are caused by human error including dropped tools, accidental contact with electrical systems, and improper work procedures. Another common cause of an arc is insulation failure.
S
What can happen if I am exposed to arc flash?
Y
Exposure to an arc flash frequently results in a variety of serious injuries, and in some cases, death. Workers have been injured even though they were 10 feet or more away from the arc center.
S
What can I do to reduce my risk to arc flash exposure?
Y
Preventive maintenance, worker training, and an effective safety program can significantly reduce arc flash exposure.
S
Are all arcs equal?
Y
No. You must conduct a hazard assessment to determine the level (intensity) of energy from the arc in calories. Then you can determine the proper personal protective equipment (PPE) needed.