Vertiv™ Liebert® IntelliSlot™ RDU101 Communications Card
The Vertiv™ Liebert® IntelliSlot™ RDU101 Communications Card enables communication between Vertiv™ products such as Trellis™ Enterprise, Trellis™ Power Insight and LIFE™ Services. It provides web access, data via SNMP and Modbus TCP for Vertiv equipment. Environmental sensor data is provided via web and SNMP.
Zapisano produkt na tablicy użytkownika
Zapisano produkt na tablicy użytkownika, aby móc wrócić do niego w przyszłości. Jeśli nie chcesz tego przedmiotu w zapisanych, można z łatwością usunąć go z tablicy użytkownika.
Zaloguj się lub załóż konto, aby zapisać to na później
- Banking
- Financial and Insurance
- Data Center/Colocation/Hosting
- Government
- Healthcare
- Retail and Wholesale
- Telecom
Vertiv™ Liebert® IntelliSlot™ RDU101 Communications Card
The Vertiv™ Liebert® IntelliSlot™ RDU101 Communications Card enables communication between Vertiv™ products such as Trellis™ Enterprise, Trellis™ Power Insight and LIFE™ Services. It provides web access, data via SNMP and Modbus TCP for Vertiv equipment. Environmental sensor data is provided via web and SNMP.
- Banking
- Financial and Insurance
- Data Center/Colocation/Hosting
- Government
- Healthcare
- Retail and Wholesale
- Telecom
Korzyści
Flexible communication regardless of device protocol. Peace of mind knowing data is transported in a secure manner. Save time configuring and updating firmware on managed devices.
Właściwości
Specyfikacja techniczna
Managing disparate systems within the data center can be challenging. With responsibilities to know the conditions of your facility at all times, keeping track of all that data may require accessing multiple systems or even performing manual, time consuming data tracking. The Vertiv™ Liebert® IntelliSlot™ RDU101 Communications Card provides remote centralized monitoring connectivity to building management systems (BMS) that use SNMP. It provides web access, data via SNMP for Vertiv equipment and environmental sensors. The RDU101 employs Ethernet networks to monitor and manage a wide range of operating parameters, alarms and notifications.
Znajdź kontakt w Twoim regionie
Kontakt z działem wsparcia produktowego
Zmień
Często zadawane pytania
- Q
- Can I obtain a list of the supported SNMP Traps and parameters from the card?
- A
- Yes, once SNMP is enabled on the card the SNMP data available from the managed device is available on the download menu display from the managed device tab. Consult the User Manual for more details.
- Q
- How many SNMP Trap targets can I configure in the Liebert® IntelliSlot™ RDU101 Communications Card?
- A
- 20
- Q
- Is the Liebert® IntelliSlot™ RDU101 Communications Card hot-swappable?
- A
- Yes, you will not be required to shut down your equipment to install this card.
- Q
- What Vertiv products are supported by the RDU101 card?
- A
- GXT5 UPS