Vertiv™ VRC Rack Cooling System, 3500 Watts
The Vertiv™ VRC rack-mounted IT cooling unit packs powerful, scalable cooling into a compact unit and has been designed to tackle some of the biggest challenges seen in edge environments. Its variable speed components provide up to 3.5 kW of scalable cooling capacity, while its compact footprint saves valuable IT floorspace for critical equipment. It is available in a self-contained and split version, allowing for flexible installation regardless of building architecture or existing equipment.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Banking, Financial and Insurance
- Education
- Government
- Healthcare
- Telecom
- Retail and Wholesale
Vertiv™ VRC Rack Cooling System, 3500 Watts
The Vertiv™ VRC rack-mounted IT cooling unit packs powerful, scalable cooling into a compact unit and has been designed to tackle some of the biggest challenges seen in edge environments. Its variable speed components provide up to 3.5 kW of scalable cooling capacity, while its compact footprint saves valuable IT floorspace for critical equipment. It is available in a self-contained and split version, allowing for flexible installation regardless of building architecture or existing equipment.
- Banking, Financial and Insurance
- Education
- Government
- Healthcare
- Telecom
- Retail and Wholesale
Specifications
The Vertiv™ VRC is a rack-mounted IT cooling solution specifically designed with ease-of-installation in mind. Coming in two different version, the VRC can match various building architectures, providing flexibility with existing installations. Both mount in a standard 19-inch IT rack and are compatible with open or enclosed racks, as well as 2-post IT racks. Equipped with variable speed components, the VRC has scalable cooling capacity up to 3.5 kW, enabling low energy consumption and operational costs. IT managers can monitor the status and performance of the server cooling system on the unit’s display or remotely using the plug-in communication card through SNMP or Modbus. A condensate pump is included to remove condensed water and help simplify condensate management.
VRC Self Contained Version
|
||||||
---|---|---|---|---|---|---|
3.5 kW (12000 BTuh) | 3.3 kW (11250 BTuh) | 441 CFM / 749 CMH | 17.3 in | 17.4 in | 38.5 in | 161 lbs |
See more product information | ||||||
VRC Split Version
|
||||||
3.5kW (12000 BTuh) | 3.3kW (11250 BTuh) | 441 CFM / 749 CMH | 10.4 in | 17.4 in | 23.7 in | 50 lbs |
See more product information |
- Vertiv™ VRC1 Self-Contained Rack Cooler User Manual SL-70723
- Vertiv™ VRC Split System VRC2 Series Rack Cooler VRC3 Series Condensing Unit User Manual SL-70722
- Vertiv™ Liebert® IntelliSlot™ RDU-SIC G2 Card User Manual SL-31323
- Vertiv™ Liebert® IntelliSlot™ RDU-SIC G2 Card Quick Installation Guide (SL-70979)
*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.